The ELC-210S compression load cell is a heavy-duty precision load cell that is made of high-quality materials. It is designed for use in harsh environments. The load cell has been meticulously designed to address the growing demand for accurate and trustworthy load measurement in structural applications. It is particularly well suited for measuring compressive loads in these applications, and it is available in a variety of sizes. Load cells with capacities ranging from 1000 to 3500 kN can be obtained for use in a variety of applications.
The compression load cells in the ELC-210S model are particularly resistant to external forces due to the way they are constructed. It also allows for less stringent mounting alignment, which minimizes the possibility of reading error, in addition to enhancing the fatigue life. The load cell is shielded from contamination by dust, moisture, and other potentially harmful substances.
Any conventional digital read-out equipment compatible with resistive strain gauge type sensors can be used to measure the readings from loadcells. Automatic data collection, storage, and transmission to a distant server at the required frequency can also be performed through the use of multiplexer/busmux digital interfaces or SDI-12 digital interfaces, depending on the application.
Measurements can be taken of all of these items, as well as the tension in the ends of stay ropes, suspension lines, and railway catenary wires. Rudrra Sensors also makes and distributes high and premium grade load indicators that are both manual and automatic tare controls, among other products. RTN-C Load Masters is one of the world's leading manufacturers and suppliers of precision-manufactured load cells, pressure transducers, and load indicators in the field of precision manufacturing. We provide a product that is both unique and long-lasting, and it has no negative side effects to speak of. There is no restriction on what you may talk about the product on this number. In addition, also we deliver a product of high quality.
Cap (Ton) | A | B | C | D | E | F | D2 | R | Weight |
100 | 150 | 38 | 22 | 150 | 10 | 20 | 75 | 200 | 14kg |
100., 150., 200T | 150 | 45 | 25 | 160 | 10 | 20 | 150 | 500 | 18kg |
Parameter | C2 | Unit |
Rated load (Emax): | 50, 100, 200, 300, 500 | T |
Maximal numbers of load cell verification Intervals (NIc): | 3000 | d |
Minimum load cell Verification intervals Intervals (Vmin): | 1% | % of rated load |
Rated output (Cn): | 2.0 + 0.1% | mV/V |
*Combined error: | 0.05 | + - % of rated output |
Temperature effect on sensitivity (Tkc): | 0.02 | + - % of rated output °C |
Temperature effect on Zero balance (Tk0): | 0.02 | + - % of rated output °C |
Zero balance: | 1.0 | + % of rated output |
Input balance (Rlc): | 750 + 5 | Ω (Ohms) |
Output resistance (Ro): | 700 + 2 | Ω (Ohms) |
Insulation resistance: | > 20000 MΩ | M Ω (Mega-Ohms) |
Safe overload: | 150 | + - % of rated capacity |
Ultimate overload: | 200 | + - % of rated capacity |
Operating temperature range: | -20 + 70 | °C / °F |
Recommend excitation: | 8.12 | V(DC or AC) |
Maximum excitation: | 24 | V(DC or AC) |
Material of elastomer: | Stainless Steel | |
Protection class: | IP67/IP68 |