Close Button

How satisfied were
you with Rudrra Sensors??

DisLike
Satisfied
Excellent

    What is 7 x 9 ?

    Platform Load Cell

    Product Description

    Single Loadcell RSL 310 have a output of 2mv/v, can hold 100, 150, 200, 250, 300, 500Kg and is IP 65-protect. It has a composition error of 0.03/0.02.

    REQUIREMENTS TO INSTALL

    • When you get the boxes out, put the equipment together close to where you're going to use it.
    • Do not put anything near walls, furniture, or other objects on all sides.
    • You should leave some space for making changes while tightening the screws. Wait until you are told to fully tighten fasteners before you do so.
    • Make sure the equipment is level and stable by setting it up and putting it together on a solid and flat surface.
    • DO NOT move the equipment on your own without help.
      • Tools that you need

        • Torque wrench with a range of at least 150 ft-lb and hex bits that fit: Six, eight, and ten mm
        • Metric and standard socket wrench sets, as well as extension tools.
        • Open-end wrench sets in both metric and standard sizes.
        • Hex wrench sets in both metric and standard sizes with extensions.
        • This is what a box cutter does.
        • In this case, a rubber mallet
        • Retaining ring pliers come in large, medium, and small sizes.
        • Pliers come in big, medium, and small sizes, so you can find the right one for the job.

    We are well known manufacturer and exporter of Platform Load Cell RSL 310 model which is in our product line. We understand the need of all our clients and design suitable product. Our products are used in smaller size economical, check weighers. To maintain the quality of our products we use high grade raw material and modern technology.

    Features

    • It has a tool steel construction for a tough job
    • Low Profile has a low profile, so it doesn't draw
    • Off-center loading: • Single point Capability with very little error.
    • Allow the platform to grow to 600X600 (mm)
    • Small, light, and cheap

    Optional:

    • Stainless Steel Structure

    Load Application Layout :

    Cable Connection Details :

    Dimension :

    Parameters : (Analog Load Cell)

    Related Load (kg.) 50 / 75 / 100 / 150 / 200 / 250 / 300 / 500

    Precision
    C2 / C3
    Composition Error
    0.03 / 0.02
    Rated Output (mv/v)
    2.0 ± 10%
    Non-Linearity (%FS)
    0.025
    Hysteresis (%FS)
    0.01
    Repeatability (%FS)
    0.02 / 0.01
    Creep (%FS/30min)
    0.03 / 0.02
    Zero Balance (%FS)
    ± 1.0
    Input Resistance (Ω)
    400 ± 10
    Output Resistance (Ω)
    350 ± 2
    Insulation Resistance(MΩ)
    ≥20000(100VDC)
    Excitation Voltage (V)
    9~15 (DC)
    Compensated temp. Range (°C)
    -10~+40
    Use Temp. Range (°C)
    -20~+60
    Temp. Effect on Zero (%FS/10°C)
    0.0020
    Temp. Effect on Span (%FS/10°C)
    0.0015
    Safe Overload (%FS)
    150
    Ultimate Overload (%FS)
    250
    Defend Grade
    IP67
    Cable
    6mm, 2.5mtr

    Similar Products

    Platform Load Cell


      What is 8 + 8 ?


      Products
      Watsup
      Share
      Email